Some essential steps for proper diesel generator maintenance ?

Diesel generator maintenance is key to ensuring that your equipment keeps running for years to come, and these 8 key points are essential for every buyer.

Diesel Generator General Inspection:

During the of the diesel generator, the exhaust device, gasoline device, DC electric device, and engine require near tracking for any leaks that may reason dangerous occurrences. As with any inner combustion engine, the right upkeep is essential. Premier Power Solutions, is one of the main Generator and Diesel gensets Manufacturers in Pakistan, well-known servicing and oil alternate.

Lubrication Service:

The engine oil must be checked while shutting down the generator at regular intervals using a dipstick. Allow the oil in the upper portions of the engine to drain back into the crankcase, and follow the engine manufacturer’s recommendations for API oil classification and oil viscosity. Keep the oil level as near as possible to the full mark on the dipstick by adding the same quality and brand of oil.

The oil and filter must also be changed at acclaimed time intervals. Check with the Diesel gensets suppliers for procedures for draining the oil and replacing the oil filter, and their disposal is to be done appropriately to avoid environmental damage or liability.

Nevertheless, it pays to use the most dependable, the highest quality oils, lubricants, and coolants to keep your engine working. Therefore, Diesel genset providers Lahore, Pakistan, it is highly advisable to purchase lubricants that comply with the Original Equipment Manufacturer’s (OEM) generic lubricant specifications.

Fuel System:

Diesel is subject to contamination and corrosion within a period of one year, and therefore regular generator set exercise is highly recommended using up stored fuel before it degrades. The fuel filters should be drained at the designated intervals due to the water vapor that accumulates and condenses in the fuel tank.

Regular testing and fuel polishing may be required if the fuel is not used and replaced in three to six months. Preventive maintenance should include a regular general inspection that includes checking the coolant level, oil level, fuel system, and starting system. The charge-air cooler piping and hoses should be inspected regularly for leaks, holes, cracks, dirt, and debris that may be blocking the fins or loose connections.

According to the marketing department of the Italy-based Visa SpA, one of the world’s leading genetics suppliers, dedicated to designing, production, sales, and rental of generating sets; some engines used in Stand-by generating set applications have had a few issues concerning diesel fuel.

“While the engine maintains its mechanical properties, it can give rise to problems related to the quality of diesel fuel. The chemical make-up of diesel fuel has changed in recent years; a certain percentage of biodiesel at low or high temperatures releases impurities, while a certain percentage of biodiesel at warm temperatures mixed with water (condensation) can be the cradle of bacterial proliferation. Besides, the reduction of Sulphur reduces lubrication, which eventually blocks the fuel injection pumps.”

Keep your Diesel Generator Clean:

Oil drips and other issues are easy to spot and take care of when the engine is nice and clean. Visual inspection can guarantee that hoses and belts are in good condition. Frequent checks can keep wasps and other nuisances from nesting in your equipment.

The more a generator is used and relied on, the more it needs to be taken care of. However, a generator set that is rarely used might not need a lot of care.

Exhaust system inspection:

In case there are leaks along the exhaust line which usually occurs at the connection points, the welds and the gaskets; they should be repaired immediately by a qualified technician.

Nevertheless, always make sure your units are serviced. Especially 24 hrs before using your generators. “For standby generators, for example, you need to have your units serviced 150hrs on average. However, if the generator is used constantly, the hours go up much quicker and in more regular intervals,” she adds.

Furthermore, Manufacturer of internal combustion engines from Pakistan, it is quite advantageous when you have maintenance kits for different service intervals.